BioTec II

🔥 Available powers

BioTec II – modern wood heating technology

BioTec II steel hot-water boilers (25–45 kW) are designed for the efficient and eco-friendly heating of family homes and medium-sized buildings. Thanks to pyrolysis technology, they achieve high fuel utilization and reliable operation.

The large combustion chamber accommodates logs up to 500 mm in length, while a single load ensures long-lasting operation and great ease of use. The boiler is equipped with a digital control system featuring a 7-inch touchscreen and a lambda probe that optimizes the combustion process for maximum efficiency.

When combined with a CAS accumulation tank, the BioTec II ensures even greater energy efficiency, additional savings, and stable heat throughout the entire heating season.

BioTec II
  • WOOD SAVING

    WOOD SAVING

    Pyrolytic combustion enables efficiency of more than 93%, which results in significant savings compared to classic wood-fired boilers.
  • WiFi

    WiFi

    The digital regulation of the boiler supports online monitoring and control of the operation of the boiler through an internet portal.
  • ONE CHARGE PER DAY

    ONE CHARGE PER DAY

    The duration of one charge is at least 4 hours at full power, with the possibility of extending it to the whole day if the need for heating is reduced.
  • LARGE TIMBER

    LARGE TIMBER

    The large fire pit allows you to burn wood up to half a meter long.

Product characteristics

  • Class 5 boiler: High operating efficiency and low harmful emissions, compliant with current European standards.

  • New generation pyrolytic combustion: Advanced technology ensures maximum energy extraction from wood with reduced fuel consumption.

  • Long burn time: A single load allows for at least 4 hours of operation at nominal heat output, with significantly longer run times during periods of lower heating demand.

  • Ember retention for up to 8 hours: Allows heating to resume without relighting the fire, reduces the need for cleaning and increases ease of use.

  • Spacious combustion chamber: Designed for logs up to 500 mm in length, facilitating easier handling and less frequent reloading.

  • CAS accumulation tank: When combined with a thermal storage tank, it achieves maximum efficiency, additional savings, and superior heating comfort.

  • 7" touchscreen controller: A multifunctional touchscreen display enables simple and intuitive system management.

  • Controller: Can control up to 2 mixed heating circuits or 1 mixed heating circuit and domestic hot water, CAS-B or CAS-BS, one solar thermal collector circuit, and one alternative boiler. With 22 different basic connection schemes, it is possible to select a boiler–accumulation tank–heating system or a boiler–heating–accumulation tank system. There are also connection schemes that allow the boiler and accumulation tank to be installed in a garage or another separate building away from the house.

  • Lambda probe for optimal combustion: Continuously monitors the combustion process and automatically adjusts boiler operation for maximum efficiency.

  • Heating system control: Standard configuration supports the management of up to two heating circuits, or one heating circuit and domestic hot water preparation.

  • WiFi connectivity: A built-in WiFi module enables monitoring and control of the heating system via smartphone, tablet, or computer.

BioTec II

Delivery, mandatory and optional equipment

BioTec II boiler (clad in thermal insulation casing) on a wooden pallet

With installed and wired:

  • boiler control with color touch screen
  • thermocouple (combustion chamber sensor)
  • flue gas sensor
  • boiler sensor
  • lambda probe
  • 2 motor drives for primary and secondary air regulation
  • modulating flue gas fan

Additional sensors in standard delivery:

  • 1 × external sensor
  • 2 × flow / return sensor / hydraulic diverter sensor
  • 3 × DHW / hydraulic diverter sensor / accumulator sensor
  • 1 × room corrector (CSK)

Cleaning brush, two scrapers and cleaning tool holder, feet with plastic pads (x4)

  • heating system storage tank (CAS (min. volume according to local regulations))
  • return protection (such as 3-way thermostatic valve (60°C) (such as ESBE VTC 512, LTC 361, LTC 381) or 3-way motorized mixing valve (safety valve))
  • for closed heating systems: thermal relief valve, safety and venting assembly (2.5 bar), expansion vessel for closed heating systems (size depends on the volume of the heating installation, including the heating buffer tank)
  • for open heating systems: expansion vessel for open heating systems (size depends on the volume of the heating installation, including the heating buffer tank)
  • CAL alarm set (speaker/light)
  • CM2K module for controlling 2 heating circuits (max. 4 pieces) via mixing valves according to external temp.
  • Room thermostat
  • Room corrector CSK-Touch

Internet monitoring and management of the boiler

Access

Easy and fast access to the web portal – anytime, anywhere! Use your smartphone, tablet or computer to intuitively read and adjust values through a modern graphical interface.

Touch screen

  • Multifunctional digital regulation for precise control of the boiler.
  • The large 7" color screen enables clear and intuitive interaction.
  • Direct control over the content displayed on the screen.
  • Simple and efficient management of boiler operation.

Additional equipment